Contact Power Solutions: +1 (888) 588-3448

Rugged MIL-STD Power Entry & Export Panels

The military power distribution product line features MIL-STD compliant power entry panels, power distribution units, and circuit protection systems suited for rugged military and federal IT applications. We specialize in creating power solutions that are compact, MIL-STD 810, MIL-STD 461, Mil Compliant, and tailored for any application. We provide COTS (Commercial Off-the-shelf) solutions as well as MOTS (Modified Off-the-shelf), Complete Custom Designs, and more!

API Technologies specializes in creating high powered, rugged, and intelligent power distribution. Our Power Entry Panels and Intelligent Power Entry and Export Panels have undergone vigorous testing in a number of areas and have met MIL-STD 461 and MIL-STD 810 requirements. This includes wide operating temperature range of - 46º C to 60 º C (-51 º F to 140 ºF.)


Rugged Power Entry & Export Panels

Reliable & Rugged
Power Entry Panels

 

Rugged MIL-STD Power Entry Panels

The Power Entry Panel (PEP) offers ideal Input/Output power interface for shelters of all classification in the DOD portfolio. It features both +24/28 VDC to 200 Amps and 3-Phase AC to 60 Amp per phase input/output distribution capability. Additionally, the PEP includes a 3-Phase 60 Amp pass through connector interface to support additional Forward Operating Base requirements. The PEP has undergone vigorous testing in number of areas and has been found to meet the Army required wide operation temperature range of -46º C to 60 º C, as well as MIL-STD 810: Shock, Vibration, Rail Impact, Water Tightness, Fungus, and MIL-STD 461E EMC requirements. Contact a sales representative for more information on the Power Entry Panel or to begin an application specific design process to fit your exact needs today!



Rugged Intelligent Power Entry/Export Panel w/ Transfer Switch

Intelligent Rugged
Power Entry/Export Panels

 

Intelligent Power Entry/Export Panel w/ Transfer Switch

The Intelligent 3-Phase Power Entry/Export Panel is designed for on the go applications in Tactical Vehicles and includes a Transfer Switch to permit reliable uptime for C4ISR equipment and other mission critical hardware in transit cases. Upon detection of poor power present from shore or community power, the Export Power Panel will transfer back to vehicle inverter operating temperature range tested to -46º C to 60 º C (-51 º F to 140 ºF.) The Power Entry and Export Panel is tested to and passes MIL-STD 461 E Army & MIL-STD 810 requirements. Contact a sales representative today to learn more about this and other specialty solutions for your unique power distribution needs.

Custom Application Options

  • Rugged Field Packaging
  • Environmentally Sealed Enclosure or Open Panel
  • Battery Charger Capability
  • Circuit Breaker Over Current Protection
  • Sequencing to Individual Outputs
  • Single Phase AC or Three Phase AC
  • Horizontal Rack Mount
  • Various Height Options
  • Non - Rack Mount Designs
  • Variety of Receptacles and Plug Configurations
  • Customer Private Label
  • Surge Suppression
  • Elapsed Time Indicator
  • Local Power Meter
  • Circuit Protection with UL Breakers
  • Various Input Voltages & Current Configurations
  • Outlet Sequencing
  • On/Off Control
  • EMI Filtering
  • Power Monitoring (Voltage and Current)
  • Power Quality Monitoring & Management
  • Buss Bars
  • Status Indicators
  • EPO
  • Wide Operating Temperature Range
  • Designed to Meet MIL-STD 810F Requirements

Technical Specifications

Part Number 7200-A-125
Power Entry Panel
7200-A-126
Power Entry and Export Panel
Input Power 208/120 VAC, 3Ø WYE 60Hz, 60A +28 VDC, 200A
+28 VDC, 200A
208/120 VAC, 3Ø WYE 60Hz, 30A
Communication Network N/A LAN 10/100 TCP/IP. TELNET, SNMPv2
Physical 13.13" H x 13.38" W x 16.10" D 7.313" H x 20.5" W x 18.61" D
Weight 72 lbs 62 lbs
Environmental Wide Operating Temperature Range per Mil-STD-810F
-46°C to 50°C (-50°F to 122°F)
Wide Operating Temperature Range per Mil-STD-810F
-46°C to 50°C (-50°F to 122°F)
Output Power J2 - 208/120 VAC, 3Ø WYE
J3 - 208/120 VAC, 25A
J4 - 120 VAC, 15A & +24 VDC, 35A
J5- 120 VAC
AUX - 120 VAC @ 15 Amps

Internal Shelter Power
(4 x 1/4 - 20 Threaded Studs AC Power)
(4 x 1/4 - 20 Threaded Studs DC Power)
Status Output Terminal Block - 10 x 6-32 Screws
J2- 120 VAC @ 20 Amps
J5- 120 VAC @ 20 Amps
J6- 120 VAC @ 20 Amps
J7- 120 VAC @ 20 Amps
J8- 120 VAC @ 20 Amps
J9 - 120 VAC @ 30 Amps
Ground Lugs Vehicle Ground - 3/8 - 16 Stud
External Ground Rod Stud - 3/8 - 16 Stud
Vehicle Ground - 3/8 - 16 Stud
External Ground Rod Stud - 3/8 - 16 Stud
Battle Mode Switch No Yes
Battery Charger Power
(When Connected to Shore Power)
28 VDC @ 5 Amps 28 VDC @ 10 Amps

Details

Part Number 7200-A-125
Power Entry Panel
7200-A-126
Power Entry and Export Panel
Connectors (J2) Export Power: MIL-C-22992 (MS90555C32412S)
(J3) Environmental Control Unit Power: MIL-C-5015 (MS3454W24-10S)
(J4) DC Power Supply: MIL-C-5015 (MS3454W20-14S)
(J5) PTIP Interface: MIL-C-5015 (MS3454W24-10SW)
(J8) GCFI Power: MIL-C-5015 (MS3452W22-2S)
(J2) Battery Charge Power: MIL-C-5015 (MS3452W16-11PW)
(J5) Roadside MEP Power: MIL-C-5015 (MS3452W22-2S)
(J6) Curbside MEP Power: MIL-C-5015 (MS3452W22-2S)
(J7) Rear MEP Power: MIL-C-5015 (MS3452W22-2S)
(J8) GCFI Power: MIL-C-5015 (MS3452W22-2S)
(J9) Radio Rack Power: MIL-C-5015 (MS3452W22-2S)
Auxiliary Connectors (J6) EPO Kill-Switch
(J7) External Status Indicator DC Signals
 

Manufacturing and Design Capability

  • Sheet and Machined Metal Design
  • Metal Fabricating and Finishing
  • PCBA Design, Simulation, and Fabrication
  • Cable Management
  • Testing
  • Circuit Simulation
  • 3D Modeling
  • Thermographic Analysis
  • Heat Management Modeling